12000W PID Adjustable Voltage Battery Charger for Lead-Acid & Lithium Battery Packs With PFC
Ultimate Charging Hub for 13.8V – 58.4V Systems: The pinnacle of power delivery for ESS and large-scale AGV fleets. Engineered to hit 13.8V, 14.6V, 27.6V, 29.2V, 55.2V, and 58.4V with uncompromising precision across multiple rated voltage models.
Programmable Massive Power: Unleashes up to 18kW of energy with full Modbus control. Features dedicated dry-contact alarm signals for “Power Good” status monitoring in critical infrastructure.
Grid-Level Safety Protocol: Advanced protection logic allows users to set specific overvoltage shutdown points. The system manages temperature-controlled recovery and short-circuit lockouts automatically.
High-Density Engineering: Reaches up to 93% efficiency with a professional 455x345x251mm design. Ideal for high-vibration and high-temperature industrial settings
- Description
| Modèle | HPS-12000-30 | HPS-12000-36 | HPS-12000-48 | HPS-12000-60 | HPS-12000-110 | HPS-12000-220 |
| Tension continue | 30V | 36V | 48V | 60V | 110V | 220V |
| Courant nominal | 320A | 266.7A | 200A | 160A | 87.3A | 43.6A |
| Plage actuelle | 0-320A | 0-266.7A | 0-200A | 0-160A | 0-87.3A | 0-43.6A |
| Puissance nominale | 12000W | |||||
| Ondulation | 500mV | 500mV | 600mV | 600mV | 1000mV | 1500mV |
| Plage optimale à courant constant | 15-30V | 18-36V | 24-48V | 30-60V | 55-110V | 110-220V |
| Précision de la tension nominale | ±1,0% | |||||
| Régulation de ligne | ± 1.0% | |||||
| Régulation de charge | ± 1.0% | |||||
| Startup&Rise Time | 1500mS,700mS/230VAC(Fully loaded) | |||||
| Plage de tension | 95-190VAC(Output Current 50%),195-265VAC(Output Curent 100%) | |||||
| Gamme de fréquence | 45Hz-65Hz | |||||
| Facteur de puissance | PF≥0.99/230VAC(Fully loaded) | |||||
| Efficacité (MAX) | 91% | 91.5% | 92% | 92% | 92.5% | 93% |
| ACCurent | <110A | |||||
| Courant de fuite | <3,0 mA/240 VCA | |||||
| Court-circuit | When the constant current is entered and the voltage is lower than 10%of the rated voltage,the output is shut down and locked after 1 second,and recovers after restarting. | |||||
| Over current | The user can set the over-current value to delay the output for 5 seconds and then shut down the output,and then resume after restarting. | |||||
| Surpression | Users can set the overvoltage value to shut down the output voltage,and restore after restart. | |||||
| Surchauffe | Shut down the output,automatically recover or restart after the temperature drops. | |||||
| Réglage de la tension de sortie | 0-33V | 0-39,6V | 0-52,8V | 0-66V | 0-121V | 0-242V |
| Réglage du courant constant de sortie | 0-320A | 0-266.7A | 0-200A | 0-160A | 0-87.3A | 0-43.6A |
| 485Communications | Protocole de communication MODBUS | |||||
| solated auxiliary power supply | 12V0.5A(Need customization) | |||||
| Commutateur à distance de sortie | Default power on,high level power off (5V-12V)(Need customization) | |||||
| Alarmsignaloutput | Power Good Signal (Dry Contact≤36V,0.1A) (Need customization) | |||||
| Température de fonctionnement | -20-+60℃ | |||||
| Humidité de fonctionnement | -20-90%RHNo condensation | |||||
| Storage temperatureandhumidity | -40-+85℃,10-95%RHNo condensation | |||||
| Résistance aux vibrations | 10-500Hz,2G10 Min/cycle,X、Y、 Ż60 Min | |||||
| insulation resistance | Input to Output:100Mhms/500VDC/25°C/70%RH | |||||
| Résistance à la pression | I/P-O/P:2KVAC IP-FG:2KVAC O/P-FG:0.5KVAC | |||||
| size | 455×345×251mm | |||||
| net weight | 22 kg | |||||