9000W PID Adjustable Voltage Battery Charger for Lead-Acid & Lithium Battery Packs With PFC - WEHO

9000W PID Adjustable Voltage Battery Charger for Lead-Acid & Lithium Battery Packs With PFC

Extreme Scale 13.8V/14.6V/27.6V/29.2V/55.2V/58.4V Power: Designed for massive industrial battery arrays. These units offer broad voltage adjustment ranges (e.g., 15-30V, 30-60V, 55-110V) to precisely charge 13.8V Lead-Acid float or 58.4V LiFePO4 packs.

Modbus Communication Integration: Features Modbus protocol via 485 communication for smart grid and factory automation integration. Supports customizable remote switch and auxiliary 12V power outputs.

Reliable Constant Current Architecture: Utilizes professional CC protection that shuts down and locks output if parameters fall out of safe range, protecting high-value lithium cells from degradation.  Heavy-Industrial Durability: Built into a robust 432x179x242mm chassis with 93% maximum efficiency. Operates reliably from -20°C to +80°C in high-demand environments.

Modèle HPS-9000-24 HPS-9000-30 HPS-9000-36 HPS-9000-48 HPS-9000-60 HPS-9000-110 HPS-9000-220
Tension continue 24V 30V 36V 48V 60V 110V 220V
Courant nominal 337.5A 270A 225A 168.8A 135A 73.6A 36.8A
Plage actuelle 0-337.5A 0-270A 0-225A 0-168.8A 0-135A 0-73.6A 0-36.8A
Puissance nominale 9000W
Ondulation 500mV 500mV 500mV 600mV 600mV 1000mV 1500mV
Plage optimale à courant constant 12-24V 15-30V 18-36V 24-48V 30-60V 55-110V 110-220V
Précision de la tension nominale    ±1,0%
Régulation de ligne    ±1,0%
Régulation de charge    ±1,0%
Startup&Rise Time    1500mS,700mS/230VAC(Fully loaded)
Plage de tension    95-190VAC(Output Current 50%),195-265VAC(Output Curent 100%)
Gamme de fréquence    45Hz-65Hz
Facteur de puissance    PF≥0.99/230VAC(Fully loaded)
Efficacité (MAX) 90% 90% 91.5% 92% 92% 92.5% 93%
ACCurent    <56A
Courant de fuite    <3,0 mA/240 VCA
Court-circuit When the constant curenitis entered and the votageis lower tian 10%of the rated votage,the outout is shut down and ockedafter1second,and recovers after restating.
Over current The user can set the over-current value to delay the oufput for5 seconds and then shut down the output,and then resume after restarting.
Surpression Users can set the overvoltage value to shut down the output voltage,and restore after restart.
Surchauffe Shut down the output,automatically recover or restart after the temperature drops.
Réglage de la tension de sortie 0-26,4V 0-33V 0-39,6V 0-52,8V 0-66V 0-121V 0-242V
Réglage du courant constant de sortie 0-337.5A 0-270A 0-225A 0-168.8A 0-135A 0-73.6A 0-36.8A
485Communications    Protocole de communication MODBUS
solated auxiliary power supply    12V0.5A(Need customization)
Commutateur à distance de sortie Default power on,high level power off(5V-12V)(Need customization)
Alarmsignaloutput  Power Good Signal(Dry Contact≤36V,0.1A)  (Need customization)
Température de fonctionnement  -20-+60℃
Humidité de fonctionnement -20-90%RH No condensation
Storage temperatureandhumidity -40-+85℃,10-95%RH No condensation
Résistance aux vibrations 10-500Hz,2G10 Min/cycle,X、Y、Z60 Min
insulation resistance Input to Output:100Mhms/500VDC/25°C/70%RH
Résistance à la pression  /P-O/P:2KVAC IP-FG:2KVACO/P-FG:0.5KVAC
size  432×179×242mm
net weight 12.5 kg