{"id":7198,"date":"2024-11-02T11:57:47","date_gmt":"2024-11-02T03:57:47","guid":{"rendered":"https:\/\/elementor.wehopower.com\/?post_type=product&#038;p=7198"},"modified":"2025-07-21T10:48:43","modified_gmt":"2025-07-21T02:48:43","slug":"sp-6000-high-power-switching-power-supply","status":"publish","type":"product","link":"https:\/\/elementor.wehopower.com\/es\/product\/sp-6000-high-power-switching-power-supply\/","title":{"rendered":"SP-6000 High Power Switching Power Supply"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><strong>Caracter\u00edsticas<\/strong><\/p>\n<p>1\u3001Voltage input range: 95-265VAC<br \/>\n2\u3001Protection type: short circuit\/overcurrent\/overvoltage\/overtemperature<br \/>\n3\u3001Power factor PF\u22670.99<br \/>\n4\u3001Working efficiency up to 93%<br \/>\n5\u3001485 communication control<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Par\u00e1metros t\u00e9cnicos<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"178\">Modelo<\/td>\n<td width=\"83\">SP-6000-24<\/td>\n<td width=\"83\">SP-6000-36<\/td>\n<td width=\"86\">SP-6000-48<\/td>\n<td width=\"97\">SP-6000-60<\/td>\n<td width=\"99\">SP-6000-110<\/td>\n<td width=\"84\">SP-6000-220<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"10\" width=\"79\">Producci\u00f3n<\/td>\n<td width=\"98\">DC voltage<\/td>\n<td width=\"83\">24V<\/td>\n<td width=\"83\">36V<\/td>\n<td width=\"86\">48V<\/td>\n<td width=\"97\">60V<\/td>\n<td width=\"99\">110V<\/td>\n<td width=\"84\">220V<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Corriente nominal<\/td>\n<td width=\"83\">250A<\/td>\n<td width=\"83\">166.6A<\/td>\n<td width=\"86\">125A<\/td>\n<td width=\"97\">100A<\/td>\n<td width=\"99\">54.5A<\/td>\n<td width=\"84\">27.2A<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Rango actual<\/td>\n<td width=\"83\">\u00a0\u00a00 &#8211; 250A<\/td>\n<td width=\"83\">0 &#8211; 166.6A<\/td>\n<td width=\"86\">0 &#8211; 125A<\/td>\n<td width=\"97\">0 &#8211; 100A<\/td>\n<td width=\"99\">0 &#8211; 54.5A<\/td>\n<td width=\"84\">0 &#8211; 27.2A<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Potencia nominal<\/td>\n<td colspan=\"6\" width=\"534\">6000W<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Onda<\/td>\n<td width=\"83\">500mV<\/td>\n<td width=\"83\">500mV<\/td>\n<td width=\"86\">600mV<\/td>\n<td width=\"97\">600mV<\/td>\n<td width=\"99\">1000mV<\/td>\n<td width=\"84\">1500mV<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Rango \u00f3ptimo de corriente constante<\/td>\n<td width=\"83\">12 &#8211; 24V<\/td>\n<td width=\"83\">18 &#8211; 36V<\/td>\n<td width=\"86\">24 &#8211; 48V<\/td>\n<td width=\"97\">30 &#8211; 60V<\/td>\n<td width=\"99\">55 &#8211; 110V<\/td>\n<td width=\"84\">110 &#8211; 220V<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Rated voltage accuracy<\/td>\n<td colspan=\"6\" width=\"534\">\u00b1 1.0%<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Regulaci\u00f3n de l\u00ednea<\/td>\n<td colspan=\"6\" width=\"534\">\u00b1 1.0%<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Regulaci\u00f3n de carga<\/td>\n<td colspan=\"6\" width=\"534\">\u00b1 1.0%<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Tiempo de inicio y subida<\/td>\n<td colspan=\"6\" width=\"534\">1500mS\uff0c700mS\/230VAC(Fully loaded\uff09<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"79\">Aporte<\/td>\n<td width=\"98\">Voltage range<\/td>\n<td colspan=\"6\" width=\"534\">95-190VAC(Output Current 50%),195-265VAC(Output Current 100%)<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Rango de frecuencia<\/td>\n<td colspan=\"6\" width=\"534\">45Hz &#8211; 65Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Factor de potencia<\/td>\n<td colspan=\"6\" width=\"534\">PF\u22670.99\/230VAC(Fully loaded)<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Efficiency(MAX)<\/td>\n<td width=\"83\">90 %<\/td>\n<td width=\"83\">91.5 %<\/td>\n<td width=\"86\">92 %<\/td>\n<td width=\"97\">92 %<\/td>\n<td width=\"99\">92.5 %<\/td>\n<td width=\"84\">93 %<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Ac Current<\/td>\n<td colspan=\"6\" width=\"534\">\uff1c56A<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Corriente de fuga<\/td>\n<td colspan=\"6\" width=\"534\">\uff1c3.0mA \/ 240VAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"79\">Protect<\/td>\n<td width=\"98\">Cortocircuito<\/td>\n<td colspan=\"6\" width=\"534\">When the constant current is entered and the voltage is lower than 10% of the rated voltage, the output is shut down and locked after 1 second, and recovers after restarting.<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Overcurrent<\/td>\n<td colspan=\"6\" width=\"534\">The user can set the over-current value to delay the output for 5 seconds and then shut down the output, and then resume after restarting.<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Overpressure<\/td>\n<td colspan=\"6\" width=\"534\">Users can set the overvoltage value to shut down the output voltage, and restore after restart<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Sobre temperatura<\/td>\n<td colspan=\"6\" width=\"534\">Shut down the output, automatically recover or restart after the temperature drops<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"79\">Function<\/td>\n<td width=\"98\">Ajuste del voltaje de salida<\/td>\n<td width=\"83\">0 &#8211; 26.4V<\/td>\n<td width=\"83\">0 &#8211; 39.6V<\/td>\n<td width=\"86\">0 &#8211; 52.8V<\/td>\n<td width=\"97\">0 &#8211; 66V<\/td>\n<td width=\"99\">0 &#8211; 121V<\/td>\n<td width=\"84\">0 &#8211; 242V<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Ajuste de corriente constante de salida<\/td>\n<td width=\"83\">0 &#8211; 250A<\/td>\n<td width=\"83\">0 &#8211; 166.6A<\/td>\n<td width=\"86\">0 &#8211; 125A<\/td>\n<td width=\"97\">0 &#8211; 100A<\/td>\n<td width=\"99\">0 &#8211; 54.5A<\/td>\n<td width=\"84\">0 &#8211; 27.2A<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">485 Communications<\/td>\n<td colspan=\"6\" width=\"534\">MODBUS Communication Protocol<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Isolated auxiliary power supply<\/td>\n<td colspan=\"6\" width=\"534\">12V 0.5A \u00a0(Need customization)<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Output remote switch<\/td>\n<td colspan=\"6\" width=\"534\">Default power on, high level power off \u00a0\u00a0\uff085V-12V\uff09\u00a0\u00a0(Need customization)<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Alarm signal output<\/td>\n<td colspan=\"6\" width=\"534\">Power Good Signal (Dry Contact\u2266\u00a036V,0.1A)(Need customization)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"79\">Ambiente<\/td>\n<td width=\"98\">Temperatura de funcionamiento<\/td>\n<td colspan=\"6\" width=\"534\">-20 &#8211; +60\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Humedad de funcionamiento<\/td>\n<td colspan=\"6\" width=\"534\">-20 &#8211; 90% RH No condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Storage temperature and humidity<\/td>\n<td colspan=\"6\" width=\"534\">-40 &#8211; +85\u2103, 10 &#8211; 95% RH No condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Resistencia a las vibraciones<\/td>\n<td colspan=\"6\" width=\"534\">10 &#8211; 500Hz, 2G 10 Min\/Cycle, X\u3001Y\u3001Z \u00a060 Min<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"79\">Safety Regulations<\/td>\n<td width=\"98\">Resistencia a aislamiento<\/td>\n<td colspan=\"6\" width=\"534\">Input to Output:100Mhms\/500VDC\/25\u2103\/70%RH<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Resistencia a la presi\u00f3n<\/td>\n<td colspan=\"6\" width=\"534\">I\/P-O\/P :2KVAC I\/P-FG :2KVAC O\/P-FG :0.5KVAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"79\">Otro<\/td>\n<td width=\"98\">Size<\/td>\n<td colspan=\"6\" width=\"534\">432*179*242mm\uff08L*W*H\uff09<\/td>\n<\/tr>\n<tr>\n<td width=\"98\">Net Weight<\/td>\n<td colspan=\"6\" width=\"534\">9 KG<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">Observaci\u00f3n<\/td>\n<td colspan=\"7\" width=\"632\">1. Todos los par\u00e1metros se miden con un voltaje de entrada de 230 VCA, carga nominal y 25 \u2103, a menos que se especifique lo contrario.<br \/>\n2. La ondulaci\u00f3n y el voltaje de ruido se miden con un osciloscopio de ancho de banda de 20 MHz con condensadores de 0,1 \u03bc y 47 \u03bc agregados al extremo de un par trenzado de 12 pulgadas y se miden con un ancho de banda de 20 MHz.<br \/>\n3. Accuracy: includes setting error, linear regulation rate and load regulation rate.<br \/>\n4. Output must be derated for low input voltage conditions, please refer to the static characteristic curve for details.<br \/>\n5. Startup time is measured under cold start, and frequent switching may increase the startup time.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><b>Static characteristic curve<\/b><\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-7189\" src=\"https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Static-characteristic-curve.png?quality=85&strip=all\" alt=\"SP-6000 High Power Switching Power Supply  title=\" width=\"880\" height=\"300\" sp-6000 high power switching supply title=\"\" srcset=\"https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Static-characteristic-curve.png?quality=85&strip=all 880w, https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Static-characteristic-curve-300x102.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Static-characteristic-curve-768x262.png?quality=85&strip=all 768w\" sizes=\"(max-width: 880px) 100vw, 880px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; Features 1\u3001Voltage input range: 95-265VAC 2\u3001Protection type: short circuit\/overcurrent\/overvoltage\/overtemperature 3\u3001Power factor PF\u22670.99 4\u3001Working efficiency up to 93% 5\u3001485 communication control &nbsp; Technical Parameters Model SP-6000-24 SP-6000-36 SP-6000-48 SP-6000-60 SP-6000-110 SP-6000-220 Output DC voltage 24V 36V 48V 60V 110V 220V Rated current 250A 166.6A 125A 100A 54.5A 27.2A Current range \u00a0\u00a00 &#8211; 250A 0 &#8211;&hellip; <a class=\"more-link\" href=\"https:\/\/elementor.wehopower.com\/es\/product\/sp-6000-high-power-switching-power-supply\/\">Continuar leyendo <span class=\"screen-reader-text\">SP-6000 High Power Switching Power Supply<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":7210,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[161],"product_categories_new":[124],"class_list":["post-7198","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-adjustable-high-power-smps","product_categories_new-pfc-function-sp-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/product\/7198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/comments?post=7198"}],"version-history":[{"count":0,"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/product\/7198\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/media\/7210"}],"wp:attachment":[{"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/media?parent=7198"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/product_category?post=7198"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/elementor.wehopower.com\/es\/wp-json\/wp\/v2\/product_categories_new?post=7198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}