{"id":7151,"date":"2024-11-02T10:10:38","date_gmt":"2024-11-02T02:10:38","guid":{"rendered":"https:\/\/elementor.wehopower.com\/?post_type=product&#038;p=7151"},"modified":"2026-03-02T15:08:25","modified_gmt":"2026-03-02T07:08:25","slug":"se-2000w-single-output-switching-power-supply","status":"publish","type":"product","link":"https:\/\/elementor.wehopower.com\/de\/product\/se-2000w-single-output-switching-power-supply\/","title":{"rendered":"SE-2000W Single Output Switching Power Supply"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><strong>Merkmale<\/strong><\/p>\n<p>Voltage input range: 90-132VAC; 180-264VAC\/254-370VDC<br \/>\nProtection type: short circuit\/overvoltage\/overcurrent<br \/>\nTemperature control fan cooling (optional)<br \/>\nConstant voltage and constant current function<br \/>\nComplete external control function: external signal shutdown, external signal<br \/>\nControl power supply output voltage and current, independent external auxiliary power supply<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Technical Parameters<\/strong><\/p>\n<table style=\"width: 100%;\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"365\" height=\"42\">Modell<\/td>\n<td width=\"120\">SE-2000-24<\/td>\n<td width=\"117\">SE-2000-36<\/td>\n<td width=\"120\">SE-2000-48<\/td>\n<td width=\"117\">SE-2000-70<\/td>\n<td width=\"133\">SE-2000-110<\/td>\n<td width=\"130\">SE-2000-220<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\" width=\"138\" height=\"285\">Ausgabe<br \/>\nCharacteristics<\/td>\n<td width=\"227\">DC-Ausgangsspannung<\/td>\n<td width=\"120\">24V<\/td>\n<td width=\"117\">36V<\/td>\n<td width=\"120\">48V<\/td>\n<td width=\"117\">70V<\/td>\n<td width=\"133\">110V<\/td>\n<td width=\"130\">220V<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Rated current<\/td>\n<td width=\"120\">83.3A<\/td>\n<td width=\"117\">55.5A<\/td>\n<td width=\"120\">41.6A<\/td>\n<td width=\"117\">28.6A<\/td>\n<td width=\"133\">18.2A<\/td>\n<td width=\"130\">9.1A<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Current range<\/td>\n<td width=\"120\">0-83.3A<\/td>\n<td width=\"117\">0-55.5A<\/td>\n<td width=\"120\">0-41.6A<\/td>\n<td width=\"117\">0-28.6A<\/td>\n<td width=\"133\">0-18.2A<\/td>\n<td width=\"130\">0-9.1A<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Nennleistung<\/td>\n<td width=\"120\">1999.2W<\/td>\n<td width=\"117\">1998W<\/td>\n<td width=\"120\">1996.8W<\/td>\n<td width=\"117\">2002W<\/td>\n<td width=\"133\">2002W<\/td>\n<td width=\"130\">2002W<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Ripple &amp;Noise(Max)<\/td>\n<td width=\"120\">200mVp-p<\/td>\n<td width=\"117\">300mVp-p<\/td>\n<td width=\"120\">300mVp-p<\/td>\n<td width=\"117\">500mVp-p<\/td>\n<td width=\"133\">600mVp-p<\/td>\n<td width=\"130\">800mVp-p<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Voltage adjustment range<\/td>\n<td width=\"120\">0-24V<\/td>\n<td width=\"117\">0-36V<\/td>\n<td width=\"120\">0-48V<\/td>\n<td width=\"117\">0-70V<\/td>\n<td width=\"133\">0-110V<\/td>\n<td width=\"130\">0-220V<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Voltage accuracy<\/td>\n<td width=\"120\">\u00b11%<\/td>\n<td width=\"117\">\u00b11%<\/td>\n<td width=\"120\">\u00b11%<\/td>\n<td width=\"117\">\u00b11%<\/td>\n<td width=\"133\">\u00b11%<\/td>\n<td width=\"130\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Linienregulierung<\/td>\n<td width=\"120\">\u00b10,5%<\/td>\n<td width=\"117\">\u00b10,5%<\/td>\n<td width=\"120\">\u00b10,5%<\/td>\n<td width=\"117\">\u00b10,5%<\/td>\n<td width=\"133\">\u00b10,5%<\/td>\n<td width=\"130\">\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Lastregulierung<\/td>\n<td width=\"120\">\u00b11%<\/td>\n<td width=\"117\">\u00b10,5%<\/td>\n<td width=\"120\">\u00b10,5%<\/td>\n<td width=\"117\">\u00b10,5%<\/td>\n<td width=\"133\">\u00b10,5%<\/td>\n<td width=\"130\">\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Startup &amp;Rise Time<\/td>\n<td colspan=\"6\" width=\"740\">1500mS,30mS\/230VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Keep Time<\/td>\n<td colspan=\"6\" width=\"740\">30mS\/230VAC(Fully loaded)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"138\" height=\"156\">Eingang<\/td>\n<td width=\"227\">Eingangsspannung<\/td>\n<td colspan=\"6\" width=\"740\">180-264VAC\/245-370VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Frequency range<\/td>\n<td colspan=\"6\" width=\"740\">45-65HZ<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Power Factor<\/td>\n<td colspan=\"6\" width=\"740\">PF\u22650.65\/230VAC(Fully loaded)<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">efficiency<\/td>\n<td width=\"120\">86%<\/td>\n<td width=\"117\">87%<\/td>\n<td width=\"120\">89%<\/td>\n<td width=\"117\">90%<\/td>\n<td width=\"133\">90%<\/td>\n<td width=\"130\">91%<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">AC Current<\/td>\n<td colspan=\"6\" width=\"740\">&lt;20A<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Leckstrom<\/td>\n<td colspan=\"6\" width=\"740\">&lt;3.0mA\/240VAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"138\" height=\"52\">Protect<\/td>\n<td width=\"227\">Short Circuit<\/td>\n<td colspan=\"6\" width=\"740\">Enter constant current<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\u00dcbertemperatur<\/td>\n<td colspan=\"6\" width=\"740\">Shut down the output,automatically recover or restart after the temperature drops<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"138\" height=\"162\">Function<\/td>\n<td width=\"227\">Output voltage adjustment<\/td>\n<td width=\"120\">0-26.4V<\/td>\n<td width=\"117\">0-39.6V<\/td>\n<td width=\"120\">0-52.8V<\/td>\n<td width=\"117\">0-79.2V<\/td>\n<td width=\"133\">0-121V<\/td>\n<td width=\"130\">0-242V<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Output constant current<br \/>\nadjustment<\/td>\n<td width=\"120\">0-83.3A<\/td>\n<td width=\"117\">0-55.5A<\/td>\n<td width=\"120\">0-41.6A<\/td>\n<td width=\"117\">0-27.7A<\/td>\n<td width=\"133\">0-18.1A<\/td>\n<td width=\"130\">0-9A<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">External potentiometer<\/td>\n<td colspan=\"6\" width=\"740\">External potentiometer control(voltage,current)<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Analog voltage control<\/td>\n<td colspan=\"6\" width=\"740\">0-5V\/0-10V control(voltage,current)<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Auxiliary power supply<\/td>\n<td colspan=\"6\" width=\"740\">12V0.5A<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Remote control switch<\/td>\n<td colspan=\"6\" width=\"740\">Default power on,high level power off (3V-12V)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"138\" height=\"114\">Environmental<\/td>\n<td width=\"227\">Operating temperature<\/td>\n<td colspan=\"6\" width=\"740\">-20-+60\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Operating humidity<\/td>\n<td colspan=\"6\" width=\"740\">-20-90%RH without condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Storage temperature<br \/>\nand humidity<\/td>\n<td colspan=\"6\" width=\"740\">-40-+85\u2103,10-95%RH without condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Vibration resistance<\/td>\n<td colspan=\"6\" width=\"740\">10-500Hz,2G10 minutes\/cycle,60 minutes for each ofX,YandZ axes<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"138\" height=\"52\">Safety<\/td>\n<td width=\"227\">Insulation resistance<\/td>\n<td colspan=\"6\" width=\"740\">Input to output:100Mhms\/500VDC\/25\u2103\/70%RH<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Pressure resistance<\/td>\n<td colspan=\"6\" width=\"740\">I\/P-O\/P:1.2KVACI\/P-FG:1.2KVACO\/P-FG:0.5KVAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"138\" height=\"54\">Andere<\/td>\n<td width=\"227\">Gr\u00f6\u00dfe<\/td>\n<td colspan=\"6\" width=\"740\">277*155*70mm(L*W*H)<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">Net weight<\/td>\n<td colspan=\"6\" width=\"740\">2.6KG<\/td>\n<\/tr>\n<tr>\n<td width=\"138\" height=\"142\">Remark<\/td>\n<td colspan=\"7\" width=\"967\">1.All parameters are measured at 230VAC input voltage,rated load and 25\u2103 unless otherwise specified.<br \/>\n2.Ripple and noise voltage are measured with a 20MHz bandwidth oscilloscope with 0.1\u03bcand47\u03bccapacitors<br \/>\nadded to the end of a 12-inch twisted pair,and measured at 20MHZ bandwidth.<br \/>\n3.Accuracy:includes setting error,linear regulation rate and load regulation rate.<br \/>\n4.Output must be derated for low input voltage conditions,please refer to the static characteristic curve for details.<br \/>\n5.Startup time is measured under cold start,and frequent switching may increase the startup time.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Structural dimensions<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-7156\" src=\"https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Structural-dimensions-SE2000.png?quality=85&strip=all\" alt=\"SE-2000W Single Output Switching Power Supply  title=\" width=\"550\" height=\"294\" se-2000w single output switching power supply title=\"\" srcset=\"https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Structural-dimensions-SE2000.png?quality=85&strip=all 764w, https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Structural-dimensions-SE2000-300x160.png?quality=85&strip=all 300w\" sizes=\"(max-width: 550px) 100vw, 550px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Derating and static characteristic curve<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-7157\" src=\"https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Derating-and-static-characteristic-curve-SE2000.jpg?quality=85&strip=all\" alt=\"SE-2000W Single Output Switching Power Supply  title=\" width=\"517\" height=\"543\" se-2000w single output switching power supply title=\"\" srcset=\"https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Derating-and-static-characteristic-curve-SE2000.jpg?quality=85&strip=all 517w, https:\/\/i1.wp.com\/elementor.wehopower.com\/wp-content\/uploads\/2024\/11\/Derating-and-static-characteristic-curve-SE2000-286x300.jpg?quality=85&strip=all 286w\" sizes=\"(max-width: 517px) 100vw, 517px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; Features Voltage input range: 90-132VAC; 180-264VAC\/254-370VDC Protection type: short circuit\/overvoltage\/overcurrent Temperature control fan cooling (optional) Constant voltage and constant current function Complete external control function: external signal shutdown, external signal Control power supply output voltage and current, independent external auxiliary power supply &nbsp; Technical Parameters Model SE-2000-24 SE-2000-36 SE-2000-48 SE-2000-70 SE-2000-110 SE-2000-220 Output Characteristics&hellip; <a class=\"more-link\" href=\"https:\/\/elementor.wehopower.com\/de\/product\/se-2000w-single-output-switching-power-supply\/\">Continue reading <span class=\"screen-reader-text\">SE-2000W Single Output Switching Power Supply<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":7152,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[161],"product_categories_new":[119,228],"class_list":["post-7151","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-adjustable-high-power-smps","product_categories_new-ac-dc-enclosed-type","product_categories_new-sesed-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/product\/7151","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=7151"}],"version-history":[{"count":0,"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/product\/7151\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/media\/7152"}],"wp:attachment":[{"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=7151"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/product_category?post=7151"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/elementor.wehopower.com\/de\/wp-json\/wp\/v2\/product_categories_new?post=7151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}