15000W PID Adjustable Voltage Battery Charger for Lead-Acid & Lithium Battery Packs With PFC - WEHO

15000W PID Adjustable Voltage Battery Charger for Lead-Acid & Lithium Battery Packs With PFC

Ultimate Charging Hub for 13.8V – 58.4V Systems: The pinnacle of power delivery for ESS and large-scale AGV fleets. Engineered to hit 13.8V, 14.6V, 27.6V, 29.2V, 55.2V, and 58.4V with uncompromising precision across multiple rated voltage models.

Programmable Massive Power: Unleashes up to 18kW of energy with full Modbus control. Features dedicated dry-contact alarm signals for “Power Good” status monitoring in critical infrastructure.

Grid-Level Safety Protocol: Advanced protection logic allows users to set specific overvoltage shutdown points. The system manages temperature-controlled recovery and short-circuit lockouts automatically.

High-Density Engineering: Reaches up to 93% efficiency with a professional 455x345x251mm design. Ideal for high-vibration and high-temperature industrial settings.

Modell HPS-15000-30 HPS-15000-36 HPS-15000-48 HPS-15000-60 HPS-15000-110 HPS-15000-220
DC voltage 30V 36V 48V 60V 110V 220V
Rated current 400A 333.3A 250A 200A 109.1A 54.5A
Current range 0-400A 0-333.3A 0-250A 0-200A 0-109.1A 0-54.5A
Nennleistung 15000W
Ripple 500mV 500mV 600mV 600mV 1000mV 1500mV
Constant current optimum range 15-30V 18-36V 24-48V 30-60V 55-110V 110-220V
Rated voltage accuracy    ± 1.0%
Linienregulierung    ± 1.0%
Lastregulierung    ± 1.0%
Startup&Rise Time    1500mS,700mS/230VAC(Fully loaded)
Voltage range    95-190VAC(Output Current 50%),195-265VAC(Output Curent 100%)
Frequency range    45Hz-65Hz
Power Factor    PF≥0.99/230VAC(Fully loaded)
Efficiency(MAX) 91% 91.5% 92% 92% 92.5% 93%
ACCurent    <110A
Leckstrom    <3.0mA/240VAC
Short Circuit Enter the constant curent and the voltage is less than 10%of therated voltage,turn off and lockthe output after 1 second,and resume after restart
Over current The user can set a delay of 5 seconds after the current value is turned off,and the output can be restored after restart.
Overpressure The user can set the overvoltage value to turn off the output voltage,and resume after restart.
Übertemperatur Turn off the output and automatically recover or restart after the temperature drops
Output voltage adjustment 0-33V 0-39.6V 0-52.8V 0-66V 0-121V 0-242V
Output constant current adjustment 0-400A 0-333.3A 0-250A 0-200A 0-109.1A 0-54.5A
485Communications    MODBUS Communication Protocol
solated auxiliary power supply    12V0.5A(Need customization)
Output remote switch Default power on,high level power off (5V-12V)(Need customization)
Alarmsignaloutput Power Good Signal (Dry Contact≤36V,0.1A)  (Need customization)
Operating temperature    -20-+60℃
Operating humidity -20-90%RHnon-condensing
Storage temperatureandhumidity -40-+85℃,10-95%RH non-condensation
Vibration resistance i0-500Hz,2G 10mins/T,X、Y、Zaxis 60 minutes each
insulation resistance Input to Output:100Mhms/500VDC/25°C/70%RH
Pressure resistance    /P-O/P:2KVAC IP-FG:2KVAC O/P-FG:0.5KVAC
size    455×345×251mm
net weight    22 kg