{"id":7769,"date":"2025-04-03T10:09:40","date_gmt":"2025-04-03T02:09:40","guid":{"rendered":"https:\/\/elementor.wehopower.com\/?post_type=product&#038;p=7769"},"modified":"2025-07-22T16:25:22","modified_gmt":"2025-07-22T08:25:22","slug":"whmu-2000-dc-to-ac-modified-sine-wave-power-inverter-with-charger","status":"publish","type":"product","link":"https:\/\/elementor.wehopower.com\/ar\/product\/whmu-2000-dc-to-ac-modified-sine-wave-power-inverter-with-charger\/","title":{"rendered":"WHMU-2000 DC to AC Modified Sine Wave Power Inverter With Charger"},"content":{"rendered":"<table style=\"width: 100%;\" width=\"100%\">\n<tbody>\n<tr>\n<td width=\"178\">\u0646\u0645\u0648\u0630\u062c<\/td>\n<td width=\"175\">WHMU-2000-1<\/td>\n<td width=\"175\">WHMU-2000-1<\/td>\n<td width=\"175\">WHMU-2000-2<\/td>\n<td width=\"175\">WHMU-2000-2<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Peak power<\/td>\n<td colspan=\"4\" width=\"700\">4000W<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">\u062c\u0647\u062f \u0627\u0644\u0625\u062f\u062e\u0627\u0644<\/td>\n<td width=\"175\">\u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u063112 \u0641\u0648\u0644\u062a<\/td>\n<td width=\"175\">\u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 24 \u0641\u0648\u0644\u062a<\/td>\n<td width=\"175\">\u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u063112 \u0641\u0648\u0644\u062a<\/td>\n<td width=\"175\">\u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 24 \u0641\u0648\u0644\u062a<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0646\u0627\u062a\u062c<\/td>\n<td colspan=\"2\" width=\"350\">100VAC \u0623\u0648 110VAC \u0623\u0648 120VAC \u00b1 5%<\/td>\n<td colspan=\"2\" width=\"350\">220VAC \u0623\u0648 230VAC \u0623\u0648 240VAC \u00b1 5%<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Unload current less than<\/td>\n<td width=\"175\">0.8 \u0623<\/td>\n<td width=\"175\">0.5 \u0623<\/td>\n<td width=\"175\">0.8 \u0623<\/td>\n<td width=\"175\">0.5 \u0623<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Output frequency<\/td>\n<td colspan=\"4\" width=\"700\">50 \u0647\u0631\u062a\u0632 \u00b1 0.5 \u0647\u0631\u062a\u0632 \u0623\u0648 60 \u0647\u0631\u062a\u0632 \u00b1 0.5 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Output waveform<\/td>\n<td colspan=\"4\" width=\"700\">Modi\ufb01ed Sine Wave<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">USB port<\/td>\n<td colspan=\"4\" width=\"700\">5 \u0641\u0648\u0644\u062a 1 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Max.ef\ufb01ciency<\/td>\n<td colspan=\"4\" width=\"700\">90%<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Input current<\/td>\n<td colspan=\"4\" width=\"700\">10 \u0623<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">\u0646\u0637\u0627\u0642 \u062c\u0647\u062f \u0627\u0644\u0625\u062f\u062e\u0627\u0644<\/td>\n<td width=\"175\">10-15.5V<\/td>\n<td width=\"175\">20-31V<\/td>\n<td width=\"175\">10-15.5V<\/td>\n<td width=\"175\">20-31V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Low voltage alarm<\/td>\n<td width=\"175\">10.5\u00b10.5V<\/td>\n<td width=\"175\">21\u00b10.5V<\/td>\n<td width=\"175\">10.5\u00b10.5V<\/td>\n<td width=\"175\">21\u00b10.5V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Low voltage protection<\/td>\n<td width=\"175\">10\u00b10.5V<\/td>\n<td width=\"175\">20\u00b10.5V<\/td>\n<td width=\"175\">10\u00b10.5V<\/td>\n<td width=\"175\">20\u00b10.5V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Over voltage protection<\/td>\n<td width=\"175\">15.5\u00b10.5V<\/td>\n<td width=\"175\">31\u00b10.5V<\/td>\n<td width=\"175\">15.5\u00b10.5V<\/td>\n<td width=\"175\">31\u00b10.5V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Low voltage recover<\/td>\n<td width=\"175\">12.3\u00b10.5V<\/td>\n<td width=\"175\">24\u00b10.5V<\/td>\n<td width=\"175\">12.3\u00b10.5V<\/td>\n<td width=\"175\">24\u00b10.5V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Over voltage recover<\/td>\n<td width=\"175\">14.8V\u00b10.5V<\/td>\n<td width=\"175\">29.5V\u00b10.5V<\/td>\n<td width=\"175\">14.8V\u00b10.5V<\/td>\n<td width=\"175\">29.5V\u00b10.5V<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"178\">Protection function<\/td>\n<td width=\"175\">Low voltage<\/td>\n<td colspan=\"3\" width=\"525\">Alarm at\u00a0\ufb01rst, voltage continously reduce. LED Red light on &amp; shut sown.<\/td>\n<\/tr>\n<tr>\n<td width=\"175\">\u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f<\/td>\n<td colspan=\"3\" width=\"525\">LED Red light on, shut down<\/td>\n<\/tr>\n<tr>\n<td width=\"175\">Over load<\/td>\n<td colspan=\"3\" width=\"525\">LED Red light on, shut down<\/td>\n<\/tr>\n<tr>\n<td width=\"175\">\u0623\u0643\u062b\u0631 \u0645\u0646 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629<\/td>\n<td colspan=\"3\" width=\"525\">Alarm at\u00a0\ufb01rst, tempurature continously rise.LED Red light on &amp; shut sown<\/td>\n<\/tr>\n<tr>\n<td width=\"175\">Short circuit<\/td>\n<td colspan=\"3\" width=\"525\">LED Red light on<\/td>\n<\/tr>\n<tr>\n<td width=\"175\">Input reverse polarity<\/td>\n<td colspan=\"3\" width=\"525\">Fuse burn-out<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Output Current<\/td>\n<td width=\"175\">15A<\/td>\n<td width=\"175\">10 \u0623<\/td>\n<td width=\"175\">15A<\/td>\n<td width=\"175\">10 \u0623<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Bulk charge<\/td>\n<td width=\"175\">15A<\/td>\n<td width=\"175\">10 \u0623<\/td>\n<td width=\"175\">15A<\/td>\n<td width=\"175\">10 \u0623<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Absorption<\/td>\n<td width=\"175\">14.6VDC<\/td>\n<td width=\"175\">28.8VDC<\/td>\n<td width=\"175\">14.6VDC<\/td>\n<td width=\"175\">28.8VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Float Charging Voltage<\/td>\n<td width=\"175\">13.8VDC<\/td>\n<td width=\"175\">27.6VDC<\/td>\n<td width=\"175\">13.8VDC<\/td>\n<td width=\"175\">27.6VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">AC Input voltage range<\/td>\n<td width=\"175\">190~260VAC<\/td>\n<td width=\"175\">90-135VAC<\/td>\n<td width=\"175\">190~260VAC<\/td>\n<td width=\"175\">90-135VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u0628\u0631\u064a\u062f<\/td>\n<td colspan=\"4\" width=\"700\">Intelligent air cooling<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Unit Size<\/td>\n<td colspan=\"4\" width=\"700\">349*180*128mm<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">N.W\/G.W<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Model WHMU-2000-1 WHMU-2000-1 WHMU-2000-2 WHMU-2000-2 Peak power 4000W Input voltage DC12V DC24V DC12V DC24V Output voltage 100VAC or 110VAC or 120VAC\u00b15% 220VAC or 230VAC or 240VAC\u00b15% Unload current less than 0.8A 0.5A 0.8A 0.5A Output frequency 50Hz\u00b10.5Hz or 60Hz\u00b10.5Hz Output waveform Modi\ufb01ed Sine Wave USB port 5V 1A Max.ef\ufb01ciency 90% Input current 10A Input voltage&hellip; <a class=\"more-link\" href=\"https:\/\/elementor.wehopower.com\/ar\/product\/whmu-2000-dc-to-ac-modified-sine-wave-power-inverter-with-charger\/\">\u0645\u0648\u0627\u0635\u0644\u0629 \u0627\u0644\u0642\u0631\u0627\u0621\u0629 <span class=\"screen-reader-text\">WHMU-2000 DC to AC Modified Sine Wave Power Inverter With Charger<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":7770,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[],"product_categories_new":[103,160],"class_list":["post-7769","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_categories_new-dc-ac-modified-sine-wave","product_categories_new-modified-sine-wave-power-inverter-witch-charger-whmu-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/product\/7769","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/comments?post=7769"}],"version-history":[{"count":0,"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/product\/7769\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/media\/7770"}],"wp:attachment":[{"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/media?parent=7769"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/product_category?post=7769"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/elementor.wehopower.com\/ar\/wp-json\/wp\/v2\/product_categories_new?post=7769"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}